My Franke Zurich Tap dripping

Franke Zurich tap Dripping Blog

Franke Zurich Tap Dripping Blog

 

If your Franke Zurich Tap dripping from either (1) the spout (2) the handle or (3) where the spout meets the base.
Please note that the Zurich ‘Filter Tap’ takes a different COLD Diverter Cartridge but otherwise, the same guide applies to the Filter Tap version of the Zurich as to the non-filter Version. The link to the Filter flow Zurich Tap is at the end of this blog.

If your Franke Zurich Tap Dripping from the Spout or the Handle then it is most likely that you need to change the valves (one or both) and / or the brass bush ring (but usually its just the valve) hot or cold. Here is our Guide 7 Easy Steps to replace Kitchen Tap Valve. Also this guide here might help How to tell which Valve needs replacing Hot or Cold or Both?

If your Franke Zurich Tap Dripping where the Spout meets the Base you might need to replace your Franke Zurich Tap O Ring Kit SP1239

Here is the link to all our Franke Zurich Kitchen Tap Spare Parts.

The manufacturers changed c.2013 from 1212R valve to 3819R valve.  We would recommend that if you do not know whether you have the SP1212 Valve OR the SP3819 valve in your Tap, then remove your own valve and check before ordering. If you don’t or cannot do this, then order the SP1212 Valve but should it turn out that you have the later valve and the new valve drips in your tap, then we cannot be responsible.

See below for valve measurements & more valuable information.

Zurich Tap Valve Measurements

Measurements Valve SP1212
133.0069.960 HOT 1212R-H
133.0069.959 COLD 1212R-C
Overall height: 50mm
Nut Height: 8mm
Diameter at thread: 21mm
Splines: 20
Height of Splines: 8mm

1212R-C (cold Valve shown here).

1212R-C (cold Valve shown here. The Hot valve looks the same but has a nick in the nut).

Measurements Valve SP3819
133.0358.057 Cold SP3819-C
133.0358.056 Hot SP3819-H
Overall height: 50mm
Nut Height: 8mm
Diameter at thread: 21mm
Splines: 20
Height of Splines: 6mm

Valve 3819R

Valve 3819R (shown here the Hot valve. Cold valve is the same without a ‘nick’ in the nut )

1212R Valve Blueprint

1212R Valve Blueprint

 

If your valve looks like this in the image below, then the brass bush is still attached and you will need to separate and reuse with the new valve, or if you cannot separate, then buy a new brass bush as well.

1212R Valve with Brass Bush still attached

1212R Valve with Brass Bush still attached


For more about changing a valve and the brass bush (ring) coming away with your old valve, please read here.

Here is Franke Filterflow Zurich Tap Spare Parts.

 

Here is the link for the Franke Zurich Tap Valve

Here is the link for the Franke Zurich Tap Brass Bush
 

2. Dripping where Spout meets Base

If it is dripping where the spout meets the base then it is most likely that you need to replace the O Rings.

Franke Zurich Tap O Rings 133.0069.151 SP1239

Franke Zurich Filter Tap Cold Diverter Cartridge 133.0201.903 SP3448

 

Franke Zurich Kitchen Tap Aerator 133.0068.760 SP1256

[/one_half]
 
 

Our Blog / Plumbing Guides section includes tips e.g. how to remove a valve. Follow the links below.

Here is Franke Filterflow Zurich Tap Spare Parts.

 
Here is Franke Filterflow Zurich Tap Spare Parts.

 

Posted in: Franke Tap Spare Parts Guides, Helpful Tips

Leave a Comment (0) ↓

Leave a Comment